How to maintain the grinder sucker and lubrication system

                How to maintain the grinder sucker and lubrication system

MK2120Precision Grinding

Maintenance of grinding machine sucker

The disk of permanent magnetic chuck or electromagnetic chuck is the basis of whether the accuracy of the grinding precision can be calculated out, should be properly maintained. If the accuracy of the work object is poor or the disk is damaged, the disk must be regrinding, only the accuracy of the disk meets the requirements, the accuracy of the work pieces can be ensured.

Maintenance of grinder lubrication system

Lubricating oil should be replaced in the first use for a month, and then replaced every 3-6 months, The oil tank is provided with an oil drain bolt. Please note that when changing the oil, the groove should be cleaned as well as the filter.